Dimensions (in inches)
KW Rating
7-1/2
29-7/8
240V
208V
11.7
8.8
7
7-1/2
5
3-1/2
2-1/4
Breaker Size
REAR
WALL
40 Amps†
2-1/4
†Note: Check local codes for required breaker size.
CENTER LINE
46-1/2
Effective January 1, 1996, the National Electrical Code requires that new
construction (not existing) utilize a 4-conductor connection to an electric range.
1/4†
Note: 30" Electric Ranges conform to U.L. requirements for 0" spacing from
walls below countertops. Allow 1-1/2" spacing from the side of the range to
adjacent vertical walls above the cooktop surface.
†
The range may be placed with
0" clearance (flush) at the back
wall and side walls if the range side
trims extend beyond the
cabinet fronts at least 1/4".
Self-Clean models only
Receptacle Locations: Locally approved flexible service cord or conduit
must be used because terminals are not accessible after range installation.
See shaded area in drawing for location of electrical outlet box. Recommended
outlet locations allow range to be installed directly against rear wall.
26-3/8*
46-3/8
Installation Information: Before installing, consult installation instructions
packed with product for current dimensional data.
*Dimension from wall to front of closed oven door.
Dimension from wall to the front of closed oven
door handle is 28-1/2."
All Hotpoint ranges are equipped
with an Anti-Tip device. The
installation of this device is
an important, required step in
the installation of the range.
Listed by
Underwriters
Laboratories
R
Specification Revised 11/05
420486
|
Grizzly Trimmer T21322 User Manual
Grundig Flat Panel Television 32 VLD 4201 BF User Manual
Harbor Freight Tools Lathe 33684 User Manual
Honeywell Air Cleaner F100 User Manual
Honeywell Wok PGF3 User Manual
Hotpoint Dishwasher HDA130S User Manual
HP Hewlett Packard Laptop 4720S User Manual
HP Hewlett Packard Tablet Accessory 344524 001 User Manual
HP Hewlett Packard Wireless Office Headset 8406A User Manual
iHome Portable Speaker IP56 User Manual